Baseline and data review
The comparison period, operating conditions, meter boundaries and data limitations. A fall in energy use needs to be checked against occupancy, weather and meter coverage before it is attributed to an improvement.
ENERGY & BUILDING PERFORMANCE
Energy audits, facility and property condition assessments, and operating investigations help you decide what to improve, repair or replace. We work with your operators to separate schedule and controls problems from equipment that needs capital investment. If savings are part of the decision, we agree on the baseline and how the change will be measured.
ENERGY & PERFORMANCE SERVICES
Choose an energy audit, FCA, PCA or existing-building investigation around the decision ahead. Agree the assets, access, records, technical depth and reporting needs before work starts.
ASHRAE Levels 1, 2 & 3 help identify opportunities, compare measures and investigate major investments.
You receive: energy-use analysis, prioritized measures, cost and savings estimates, assumptions and next steps at the agreed audit depth.
Compare audit levels →Understand existing equipment and enclosure condition, deferred maintenance and renewal needs before planning repairs or replacement.
You receive: documented observations, condition findings and prioritized renewal recommendations within the agreed scope.
See condition-assessment experience →Support property due diligence with a site-specific review of visible conditions, available records and staff interviews.
You receive: a property condition report, material deficiencies, opinions of repair costs and identified investigation needs.
See property-assessment experience →Retrocommissioning and recommissioning investigate how existing systems operate against current facility requirements.
You receive: findings, prioritized actions, verification of agreed corrections and updated operating records.
Explore EBCx →FOLLOW THE EVIDENCE
Confirm meter identity, coverage, units, period and operating conditions. Missing or unreliable readings limit what the comparison can establish.
Review schedules, loads, weather, overrides and system behavior. A change in consumption is a question to investigate before claiming savings.
Compare the response using the agreed measurement approach. Record adjustments, limitations and follow-up needs.
Illustrative relationships. Scope and acceptance evidence are agreed for each project. No connection to live equipment.
Metering & data assurance. Check meter coverage, point identity and trend quality before those values become a baseline or performance finding. Explore Data Assurance Cx →
Monitoring & ongoing performance. With monitoring-based Cx and fault detection and diagnostics (FDD), we review flagged conditions, check them against field operation and verify the response after an approved correction. Explore monitored performance →
Explore energy-audit experience
WHAT YOUR OPERATING TEAM RECEIVES
The agreed assessment, audit or monitoring scope defines the analysis and records. Findings distinguish observed condition, estimated opportunity and verified operating response.
The comparison period, operating conditions, meter boundaries and data limitations. A fall in energy use needs to be checked against occupancy, weather and meter coverage before it is attributed to an improvement.
Observed behavior, likely causes and recommended actions, with implementation costs and savings estimates at the agreed study depth. Separate operational corrections, repairs and capital measures so the owner can plan the next investment.
Assess the effect of an approved improvement using a defined baseline, reporting period, measurement method and responsibilities. Report results and relevant adjustments for changes in load, schedules and other operating conditions within the agreed M&V scope.
Explore energy data, findings and follow-up in the dashboard demonstration →
See how equipment, operating data and models inform an operator’s decision →
Savings and performance results are project-specific. Dashboard trends alone do not establish verified savings; the measurement approach and relevant operating conditions determine what the comparison can support.
BUILDING SCIENCE & INDOOR CONDITIONS
Hot or cold spaces, humidity concerns and ventilation questions can involve the enclosure, HVAC, controls, occupancy and operating schedules.
Define the assessment around the reported condition, available records and measurements needed. The scope identifies specialist investigation separately where required.
Bring: the affected spaces, when the condition occurs, how the spaces are used, relevant drawings, sequences, service history and any existing measurements.
Agree: the systems and spaces included, the intended assessment, access and observation periods, and the project criteria against which findings will be reviewed. A single spot reading may not represent another season or operating condition.
Review the available enclosure details, shading, insulation and reported moisture concerns alongside ventilation, temperature control, schedules and operating modes. Identify where the records and observed conditions do not agree.
Document the evidence: record the evidence for a concern and the further investigation needed. Observations alone do not establish a hidden assembly condition or a cause.
The agreed IEQ/IAQ assessment identifies the parameters, locations, duration, instrument requirements and comparison criteria before measurements begin. Temperature, relative humidity, airflow or selected indoor-air measurements may be relevant depending on the question.
Coordinate specialist work: sampling, laboratory analysis, invasive investigation or other specialist services are identified separately where needed, with qualified providers and responsibilities agreed before work proceeds.
The agreed handoff: the assessment boundary, records reviewed, measurement locations and conditions, documented observations, data limitations and findings tied to the owner's question.
Recommendations distinguish proposed controls or operational follow-up, enclosure investigation and specialist evaluation. Include responsible parties and a way to check the effect of an approved change before calling the concern resolved.